What conditions will make the sensors call for heat?

The CIT-1, GIT-1 & SIT-6E sensors all call for heat when they sense conditions with both a temperature below 38 °F (3.33 °C) and moisture on their moisture grid. Click here to see more about Snow & Ice sensors

read more

PD Pro Snow Management System Control: Next

PD Pro with Broader Input Voltage Range

Because you need a modest snow melting system – perhaps pilot duty sized – and you’re looking for an ideal controller for it, look into Environmental Technology Inc.’s Snow Switch® Model PD Pro, the ice and...

read more

Temperature Sensor Placement?

read more

Can I extend the sensor wire and how far away can I locate the sensors?

by David Mays | Aug 04, 2011 |

CIT-1, Frequently Asked Questions, GIT-1, SIT-6E, wire

|
0 Comments

Yes. The sensor wire can be extended up to 500 feet with #18 awg wire and 2000 feet with #12 awg wire.

read more

Why isn't my sensor turning on my system when it is snowing outside?

by David Mays | Aug 04, 2011 |

CIT-1, Frequently Asked Questions, GIT-1, Sensors, SIT-6E

|
2 Comments

When we say sensor, we are talking about a CIT-1, GIT-1 or a SIT-6E (or one of their predecessors). A sensor cannot switch a system on its own and must be installed with a control (or control panel). If your system is using a device that looks like...

read more

Can I extend the wires and how far away can I locate the sensors?

by David Mays | Aug 04, 2011 |

CIT-1, Frequently Asked Questions, GIT-1, SIT-6E

|
0 Comments

Yes. The sensor wires can be extended up to 500 feet with #18 awg wire and 2000 feet with #12 awg wire.

read more